Alt

For the three-phase PWM inverter, there are three commonly used coefficients to indicate the DC voltage utilization level, i.e.

Modulation Level (调制度)

M = \cfrac{V_R}{V_T}

where V_R is the magnitude (note, not fundamental amplitude) of modulation wave, V_T is the magnitude of carrier wave.
When M \leq 1, there is no distortion in the output. While M > 1 means the output is distorted from the modulation wave.

DC Voltage Utilization Ratio (直流电压利用率)

M_u = \cfrac{V_{\rm 1max}} {V_{\rm dc}}

where V_{\rm dc} is the DC voltage. For single phase output application, V_{\rm 1max} is the maximum amplitude of phase fundamental voltage. For three phase output application, V_{\rm 1max} is the maximum amplitude of line-line fundamental voltage.

For single phase SPWM, the maximum M before distortion is M=1. At M=1, the amplitude of fundamental voltage is V_{\rm dc}/2, thus the DC voltage utilization ratio M_{u \rm\ 1-Phase\ SPWM}=1/2.

For three phase SPWM, the maximum M before distortion is M=1. At M=1, the amplitude of fundamental voltage is \sqrt{3}V_{\rm dc}/2, thus the DC voltage utilization ratio M_{u \rm\ 3-Phase\ SPWM}=\sqrt{3}/2.

In order to Increase the M_u of three-phase Y-connected motor, the third-order harmonic can be added to the SPWM, named as THIPWM. When the amplitude of third-order harmonic is 1/6 of the SPWM, the method is named as THIPWM1/6, as shown below.

Alt

The modulation wave magnitude of THIPWM1/6 is \sqrt{3}/2 of the SPWM. Thus, when M=1, the M_u of THIPWM1/6 is 2/\sqrt{3} of SPWM. Consequently, the DC voltage utilization ratio of THIPWM1/6 M_{u\rm\ 3-Phase\ THIPWM1/6} = 1.

Also, for SVPWM the DC voltage utilization ratio is the same as THIPWM1/6, thus M_{u\rm\ 3-Phase\ SVPWM} = 1

Modulation Index (调制系数) or Voltage Utilization Level

M_i = \cfrac{V_{1\rm max}}{V_{1\rm max\ 6-step}}

where {V_{1\rm max\ 6-step}} is the amplitude of the fundamental voltage (the green line below) of square form modulation wave (the blue line below) with M=1.

Alt

The fundamental wave of the square wave has the formula 4\sin{\theta}/\pi, thus

V_{\rm 1max\ 6-step}=\cfrac{4}{\pi}\cfrac{V_{\rm dc}}{2}=\cfrac{2}{\pi}V_{\rm dc}.

Then,

M_i = \cfrac{\pi}{2}\cfrac{V_{\rm 1max}}{V_{\rm dc}}

or,

V_{\rm 1max}=\cfrac{2V_{\rm dc}}{\pi}M_i

Consequently, for three-phase SPWM with M=1, the M_i is

M_{i\ \rm 3-Phase\ SPWM}=\cfrac{\pi}{2}\cfrac{1}{V_{\rm dc}}\cdot \cfrac{V_{\rm dc}}{2}=\cfrac{\pi}{4}\approx0.785

For three-phase THIPWM1/6 and SVPWM with M=1, the M_i is

M_{i\ \rm 3-Phase\ THIPWM1/6}=M_{i\ \rm 3-Phase\ SVPWM}=\cfrac{\pi}{4}\cfrac{2}{\sqrt{3}}=\cfrac{\pi}{2\sqrt{3}}\approx0.907

Categories: Motor

0 Comments

Leave a Reply

Your email address will not be published.